The constant with a value of 2.69×105 has units of C mol−1 V−1/2
For novices in electrochemistry, the predictions of this equation appear counter-intuitive, i.e. that ip increases at faster voltage scan rates. It is important to remember that current, i, is charge (or electrons passed) per unit time. In cyclic voltammetry, the current passing through the electrode is limited by the diffusion of species to the electrode surface. This diffusion flux is influenced by the concentration gradient near the electrode. The concentration gradient, in turn, is affected by the concentration of species at the electrode, and how fast the species can diffuse through solution. By changing the cell voltage, the concentration of the species at the electrode surface is also changed, as set by the Nernst equation. Therefore, a faster voltage sweep causes a larger concentration gradient near the electrode, resulting in a higher current.
Uses
Using the relationships defined by this equation, the diffusion coefficient of the electroactive species can be determined. Linear plots of ip vs. ν1/2 provide evidence for a chemically reversible redox process vs the cases where redox causes major structural change in the analyte. For species where the diffusion coefficient is known (or can be estimated), the slope of the plot of ip vs. ν1/2 provides information into the stoichiometry of the redox process.
A more general investigation method is the plot of the peak currents as function of the scan rate on a logarithmically scaled x-axis. Deviations become easily detectable and the more general fit formula
can be used.
In this equation is the current at zero scan rate at the equilibrium potential . In the electrochemical lab experiment may be small but can nowadays easily be monitored with a modern equipment. For example corrosion processes may lead to a not vanishing but still detectable . When and x is close to 0.5 a reaction mechanism according to Randles Sevcik can be assigned.
An example for this kind of reaction mechanism is the redox reaction of species as an analyte (concentration 5mM each species) in a highly concentrated (1M) background solution on graphite electrode.
Oxidation and reduction peak currents as function of the scan rate (x-axis, logarithmically scaled). Details as cyclic voltammogramms in Cyclic voltammetry. Data on GitHub
A more detailed plot with all fit parameters can be seen here.
References
^P. Zanello, "Inorganic Electrochemistry: Theory, Practice and Application" The Royal Society of Chemistry 2003. ISBN0-85404-661-5
^ Allen J. Bard and Larry R. Faulkner, "Electrochemical Methods: Fundamentals and Applications" (2nd ed.) John Wiley & Sons 2001. ISBN0-471-04372-9